Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient
Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient

Portable Patient Monitor 12'' Screen Multiparameter Handheld Hospital Monitoring Patient

2024-03-22 17:59:41  

12'' Screen Hospital Portable Multiparameter Patient

  • Model No : ZM-M150
  • Features :
  • High resolution 12.1-inch TFT color display

  • Standard parameters: ECG, Respiration, PR, NIBP, SpO2, TEMP,

  • VGA output for external display

  • Maximum 8 channel waveform synchronous display

  • Built in rechargeable lithium battery pack

  • Three working modes: monitoring, operation and diagnosis

  • Data and waveforms color adjustable

  • Arrhythmia analysis and S-T segment analysis

  • Suitable for adult, pediatric and neonatal patients

  • Display 7 channel ECG waveforms on one screen, cascade ECG waveform display

  • Built in battery for up to 2 hours of continuous operation

  • System software can be upgraded via USB

Options

       IBP, EtCO2 , Thermal printer, Touch screen

ECG 

Lead Mode                   5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection              I, II, III, avR, avL, avF, V, 

Waveform                     2 ch 

Lead mode                   3 Leads ( R, L, F or RA, LA, LL)

Lead selection              I, II, III, 

Waveform                    1 ch 

Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV,  auto 

HR and Alarm  

      Range 

      Adult                     15 ~ 300 bpm

      Neo/Ped               15 ~ 350 bpm

      Accuracy               ± 1% or ± 1bpm,which great

      Resolution            1 bpm

     Sensitivity              > 200 (uV ) 

Differential Input Impedance  > 5 MΩ

CMRR

      Monitor                 > 105 dB 

     Operation              > 105 dB

     Diagnosis              > 85 dB

Electrode offset potential  ±300mV

Leakage Current       < 10 uA

Baseline Recovery    < 3 S  After Defi.

ECG Signal Range     ±8 m V ( Vp-p ) 

Bandwidth    

     Surgery                 1 ~ 15 Hz

     Monitor                  0.5 ~ 35 Hz

     Diagnostic             0.05 ~ 100 Hz

Calibration Signal    1 (mV ),  Accuracy :±5%  

ST Segment Monitoring Range   

Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting  

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC 

    Alarm     Available

    Review    Available 

RESPARATION 

Method      Impedance between R-F(RA-LL)

Differential Input Impedance    >2.5 MΩ

Measuring Impedance Range:  0.3~5.0Ω

Base line Impedance Range:    0 – 2.5  KΩ

Bandwidth     0.3 ~ 2.5 Hz

Resp. Rate 

Measuring and Alarm Range 

     Adult                0 ~ 120 rpm

     Neo/Ped          0 ~ 150 rpm 

Resolution                      1 rpm

Accuracy                      ±2 rpm 

Apean Alarm            10 ~ 40 S 

NIBP 

Method                Oscillometric

Mode        Manual, Auto, STAT

Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode 5 Min

Pulse Rate Range    40 ~ 240 bpm

Alarm Type            SYS, DIA, MEAN

Measuring and alarm range    

Adult Mode

             SYS   40 ~ 270 mmHg

             DIA    10 ~ 215 mmHg

             MEAN  20 ~ 235 mmHg 

Pediatric Mode

             SYS   40 ~ 200 mmHg

             DIA    10 ~ 150 mmHg 

             MEAN  20 ~ 165 mmHg
Neonatal Mode 

             SYS   40 ~ 135 mmHg

             DIA    10 ~ 100 mmHg

             MEAN   20 ~ 110 mmHg 

Resolution 

              Pressure    1mmHg

              Accuracy

              Pressure  

Maximum Mean error     ±5mmHg

Maximum Standard deviation  ±8mmHg 

Overpressure Protection

             Adult Mode        297±3 mmHg 

             Pediatric Mode  240±3 mmHg

             Neonatal Mode  147±3 mmHg 

SpO2 

Measuring Range          0 ~ 100 %

Alarm Range                 0 ~ 100 %

Resolution                     1 %

Accuracy                      70% ~ 100%  ±2 %

                                     0%  ~  69%  unspecified

Actualization interval   about 1 Sec.

Alarm Delay                  10 Sec. 

Pulse Rate 

Measuring and Alarm Range  0~254bpm

Resolution                        1bpm 

 Accuracy                         ±2bpm 

TEMPERATURE 

Channel      1

Measuring and Alarm Range  0 ~ 50  C

Resolution                          0.1~C

Accuracy                          ±0.1~C 

Actualization interval about 1 Sec.

Average Time Constant   < 10 Sec. 

IBP 

Label      ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range 

    ART                           0 ~ 300 mmHg

    PA                             -6 ~ 120 mmHg

    CVP/RAP/LAP/ICP  -10 ~ 40 mmHg

    P1/P2                       -10 ~ 300 mmHg     

Press Sensor 

Sensitivity                      5  uV/V/mmHg 

   Impedance                 300-3000Ω

   Resolution                 1 mmHg 

   Accuracy                    ±2% or ±1mmHg, which great about 1 Sec.