China Professional Medical Devices Supplier, Contact us at WhatsApp +86-13510176578

Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen
Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen

Hospital Patient Monitor Multi-parameter Patient Monitoring Device 15'' Touch Screen

2024-03-07 15:56:42  

15'' Touch Screen Patient Monitoring Device

  • Model No : ZM-M151
  • Features :
  • 15” high resolution color TFT display with maximum 13 waveforms

  • Full touch-screen enables intuitive operation by clicking on the specific parameters 

  • of the waveform in real time, standard configuration includes the navigation knob

  • Pacemaker detection, electrosurgical interference proof

  • Defibrillation protection and defibrillation synchronization

  • SD Card slot enable memory extension for large data storage

  • USB and serial port enable abundant future upgrades

  • VGA output and Analog output

  • OxyCRG available to judge the respiration and circulation function for neonate

  • Large font display

  • Arrhythmia and S-T segment analysis

  • Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)

  • Nurse Call function and bi-directional communication with MFM-CMS central station

  • Multi language: English/Simplified Chinese/Traditional Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.

  • Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR

  • Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2, 

  • CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory

  • Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.

  • Clinical data can be viewed and managed via Patientcare viewer software (To be released)

  • Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection

  • Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.

ZM-M151 supports

DC power input and to adapt to a variety of environmental conditions

External recorder can print the recorded waveform data and other information in real time

External the EtCO2 interface can be connected to the mainstream CO2 module to facilitate the clinical needs

Drug concentration in titration calculations to support the event functions to customize and record

Up to 32 TCP / IP network connection composed of a central information system

Wireless networking

Options 
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer

Electrocardiogram (ECG)

Input mode Five-lead ECG input / three-lead ECG input

Lead selection I, II, III, aVR, aVL, aVF, V-

Gain selection AUTO,0.25X,0.5X,1X,2X,4X

Operating mode Diagnostic mode, monitoring mode, operation mode

Calibration signal 1mV ±5%

Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection.

Pacemaker at the same time use Support

Electrode off instructions Each electrode (RL excluded)

Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s

Common mode rejection ratio ≥90dB

Input impedance ≥5.0MΩ 

Heartrate (HR)                          

Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm

Resolution 1 bpm

Accuracy < ±5bpm

Heart rate sensitivity ≥0.20mVp-p

Alarm range 15 to 350 bpm, upper and lower limits

Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm 

message text prompts, there are three levels of alarm 

Pulse Oximetry

SPO2 Range:                          1% to 99%

Resolution:                              1%

Accuracy:                                70% to 99% range: ±2%;

1% to 69% range:                    ±5%;

Method:                                  Dual wavelength LED 

ST-segment

Measurement range -2.0~+2.0mV

Measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,Whichever is greater; Other range: undefined

Resolution 0.01mV

ST-segment update cycle 10s

ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable 

Arrhythmia analysis

Arrhythmia types 13 kinds of (scalable) 

Respiration Rate

Rate:                                  2 to 120 bpm (CO2)

Resolution:                        1 breath/min

NIBP (Non-invasive Blood Pressure)

Technique:                        Oscillometric during inflation

Range:                               Adult/Pediatric: 40 to 240 mmHg

Neonate:                           10 to 150 mmHg

Measurement Cycle:         < 40 sec. typical

Automatic Measurement

Cycles (Selectable):          2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr

STAT Mode:                      5 minutes of continuous readings

Max. Allowable Cuff

Pressure: Adult:                300mmHg

Pediatric:                          240 mmHg;

Neonate:                          150 mmHg

Resolution:                       1 mmHg

Transducer Accuracy:       ±2 mmHg or ±2% of reading,

Heart (Pulse) Rate

Range:                              30 to 250 bpm

Accuracy:                        ±2 bpm or ±3%, whichever is greater

EtCO2 technological index

Interface form External interface

Range of

measurement 0~10 kPa or (0~75) mmHg

precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、

(5.5kPa~10.0kPa)the error is ±0.7kPa

Alarm upper limit 2.1~13.2 kPa

Alarm lower limit 0~6.5 kPa

time 12s

EtCO2 exist

Unit kPa / mmHg / %

Compatibility  

external main stream and side stream are compatible

IBP technological index

Measured channel Single way and double way are optional

Range of measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)

                                      MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)

                                      DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)

Mean error ≤±0.4kPa (±3mmHg)

Range of alarm SYS: Upper limit   0.3kPa~53.3kPa(2mmHg~400mmHg)

                                      Lower limit   0kPa~53.1kPa(0mmHg~398mmHg)

MEAN:  Upper limit    0.3kPa~53.3kPa (2mmHg~400mmHg)

                Lower limit   0kPa~53.1kPa (0mmHg~398mmHg)

DIA:      Upper limit    0.3kPa~53.3kPa ( 2mmHg~400mmHg)

                Lower limit   0kPa~53.1kPa ( 0mmHg~398mmHg)

Measured unit mmHg/kPa

Specification of sensor DPT-248(space)

Consumables mode SCW-UTAH-01


Standard Accessaories:

ECG Cable (5 Leads) ...... 1Pcs

SpO2 Cable (Adult)  ........ 1Pcs

TEMP Probe (Adult)  ....... 1Pcs

NIBP Cuff (Adult)  ............ 1Pcs

NIBP Tube(150cm)  ......... 1Pcs

Wall mount with basket .... 1pcs

Remote control .................1pcs

Ground Cable   ................ 1Pcs

Power Cable  ................... 1Pcs

Cleaning Cloth  ................ 1Pcs