China Professional Medical Devices Supplier, Contact us at WhatsApp +86-13510176578

Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display
Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display

Patient Monitor Multi Parameter Device ICU Medical Equipment 15'' TFT Display

2024-03-07 16:08:57  

15'' Multi Parameter ICU Medical Patient Monitor

  • Model No : ZM-M152
  • Features :
  • High resolution 15” color TFT display
  • 12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
  • Light weight, compact and portable
  • Built-in rechargeable lithium battery 
  • Unique human voice alarm
  • Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
  • Powerful storage: Maximum 720 Hour graphic and tabular trends of all
  • Parameters, up to 10000 NIBP review ,200alarm review ,2Hours of all waveforms
  • System software can be upgraded through network
  • Data and waveforms color be adjustable
  • Arrhythmia analysis and ST segment analysis
  • Suitable for adult, paediatric and neonatal patient


Options 
Invasive Blood Pressure (IBP)
Carbon dioxide ( CO2) Module
Thermal Printer
Touch Screen
Three display output: TTL / CMOS LCD, LVDS LCD and standard VGA output


ECG 

Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection I, II, III, avR, avL, avF, V, 

Waveform 2 ch 

Lead mode 3 Leads ( R, L, F or RA, LA, LL)

Lead selection I, II, III, 

Waveform 1 ch 

Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto HR and Alarm  

Range 

Adult 15 ~ 300 bpm

Neo/Ped 15 ~ 350 bpm

Accuracy ± 1% or ± 1bpm, which great

Resolution 1 bpm

Sensitivity > 200 (uV ) 

Differential Input Impedance > 5 MΩ

CMRR

         Monitor > 105 dB 

         Operation > 105 dB

         Diagnosis > 85 dB

Electrode offset potential ±300mV

Leakage Current < 10 uA

Baseline Recovery < 3 S After Defi.

ECG Signal Range ±8 m V ( Vp-p ) 

Bandwidth    

         Surgery 1 ~ 15 Hz

         Monitor 0.5 ~ 35 Hz

         Diagnostic 0.05 ~ 100 Hz

Calibration Signal 1 (mV ), Accuracy : ±5%  

ST Segment Monitoring Range   

Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting  

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC 

Alarm Available

Review Available 

RESPARATION 

Method Impedance between RF (RA-LL)

Differential Input Impedance >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth 0.3 ~ 2.5 Hz

Resp. Rate 

Measuring and Alarm Range 

         Adult 0 ~ 120 rpm

         Neo/Ped 0 ~ 150 rpm 

Resolution 1 rpm

Accuracy ±2 rpm 

Apean Alarm 10 ~ 40 S 

NIBP 

Method Oscillometric

Mode Manual, Auto, STAT

Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode 5 Min

Pulse Rate Range 40 ~ 240 bpm

Alarm Type SYS, DIA, MEAN

Measuring and alarm range    

Adult Mode

             SYS 40 ~ 270 mmHg

             DIA 10 ~ 215 mmHg

             MEAN 20 ~ 235 mmHg 

Pediatric Mode

             SYS 40 ~ 200 mmHg

             DIA 10 ~ 150 mmHg 

             MEAN 20 ~ 165 mmHg
Neonatal Mode 

             SYS 40 ~ 135 mmHg

             DIA 10 ~ 100 mmHg

             MEAN 20 ~ 110 mmHg 

Resolution 

              Pressure 1mmHg

              Accuracy

              Pressure  

Maximum Mean error ±5mmHg

Maximum Standard deviation ±8mmHg 

Overpressure Protection

             Adult Mode 297±3 mmHg 

             Pediatric Mode 240±3 mmHg

             Neonatal Mode 147±3 mmHg 

SpO2 

Measuring Range 0 ~ 100 %

Alarm Range 0 ~ 100 %

Resolution 1 %

Accuracy 70% ~ 100% ±2 %

                0% ~ 69% unspecified

Actualization interval about 1 Sec.

Alarm Delay 10 Sec. 

Pulse Rate 

Measuring and Alarm Range 0~254bpm

Resolution 1bpm 

Accuracy ±2bpm 

TEMPERATURE 

Channel 1

Measuring and Alarm Range 0 ~ 50 C

Resolution 0.1~C

Accuracy ±0.1~C 

Actualization interval about 1 Sec.

Average Time Constant < 10 Sec. 

IBP 

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range 

           ART 0 ~ 300 mmHg

           PA -6 ~ 120 mmHg

          CVP/RAP/LAP/ICP -10 ~ 40 mmHg

          P1/P2 -10 ~ 300 mmHg     

Press Sensor 

Sensitivity 5 uV/V/mmHg 

Impedance 300-3000Ω

Resolution 1 mmHg 

Accuracy ±2% or ±1mmHg, which great about 1 Sec. 


Standard accessories:

ECG Cable (5 Leads)  ......1Pcs

SpO2 Cable (Adult)   ........1Pcs

TEMP Probe (Adult)   .......1Pcs

NIBP Cuff (Adult)   ............1Pcs

NIBP Tube (150cm)   ........1Pcs

Ground Cable      ..............1Pcs

Power Cable       ...............1Pcs

Cleaning Cloth     ..............1Pcs